ElectronBeamGun | Power | 15kW |
The Gun is installed inside the vacuum chamber and is immovable mechanically, but- distance from the edge of the gun (lower part) to the welded piece surface |
150 – 500 mm |
|
Voltage | 60kV | |
Beam current | 10-250mA | |
Long cathode life, minMagnetic focusing with minimum beam diameter,- beam current 10 mA
– beam current 250 mA Water cooling (additional water cooling system) Beam deflection using XY magnetic coil, deflection angle |
30 h0.2 mm
0.6 mm 1kW +/- 7 degree |
|
Cathode heating and bias unit to control the gun functioning | ||
Vacuum | Gun Vacuum and welding vacuum | 10-4 to 10-5 mBar |
VacuumChamber | – Material: SS- Motorized Door- X-Ray Protected
– View Port – Dimension |
Bench mounted
2 2.2×1.2×1.4m |
WorkBench | Movement AccuracyRotary manipulatorLoading capacity
Faceplate diameter |
0.5mm0-360 degree500kg
150mm |
Control &Monitoring | – CNC Controlling System- PLC control | |
HV powersupply | 15kW/20-60kV adjustable/ voltage stability 0.1% / beam current 0-250mA adjustable/ including deflection and focus and cathode power supply. |
ElectronBeam
Gun |
Power | 10kW |
– distance from the edge of the gun (lower part) to the welded piece surface | 150 – 500 mm | |
Voltage | 60kV | |
Beam current | 10-170mA | |
Long cathode life, minMagnetic focusing with minimum beam diameter,
– beam current 10 mA – beam current 170 mA Water cooling (additional water cooling system) Beam deflection using XY magnetic coil, deflection angle |
30 h
0.2 mm 0.6 mm 1kW +/- 4 degree |
|
Cathode heating and bias unit to control the gun functioning | ||
Vacuum | Gun Vacuum and welding vacuum | 10-4 to 10-5 mBar |
VacuumChamber | – Material: SS- Motorized Door
– X-Ray Protected – View Port – Dimension |
Bench mounted
1 1×1.2x1m |
WorkBench | Movement AccuracyRotary manipulator
Loading capacity Faceplate diameter |
0.5mm0-360 degree
50kg 150mm |
Control &Monitoring | – CNC Controlling System- PLC control | |
HV powersupply | 10kW/20-60kV adjustable/ voltage stability 0.1% / beam current 0-170mA adjustable/ including deflection and focus and cathode power supply. |